Title: Estimating the Extent and Thickness of DNAPL within the A/M Area of the Savannah River Site

Technical Report ·
DOI:https://doi.org/10.2172/606894· OSTI ID:606894
 [1]; ; ;
  1. Westinghouse Savannah River Company, AIKEN, SC (United States)

The objective of this study is to refine the current conceptual model for the extent, character, and thickness of DNAPL contamination in the A/M Area. The evaluation is based upon historical records of operations and waste management and on detailed screening of historical groundwater concentrations against solubility limits. The topology of the Green Clay confining zone is used as the primary factor determining DNAPL pool thickness and resulting migration paths.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-96SR18500
OSTI ID:
606894
Report Number(s):
WSRC-RP-96-0574; ON: DE98052106; TRN: 98:005495
Resource Relation:
Other Information: PBD: 20 Dec 1996
Country of Publication:
United States
Language:
English