Calculated and measured depth dose profiles in a phantom exposed to neutron radiation fields
An accurate evaluation of doses caused by external sources of neutron radiation depends on knowledge of the transport of radiation inside the human body. Health physicists use two primary methods for studying this radiation transport: computer calculations and measurements. Both computer calculations and measurements were performed under well controlled, nearly identical conditions to determine the extent of their agreement. A comparison of the dose profiles predicted by both measurements and calculations was thus possible. The measurements were performed in a cylindrical phantom made of tissue equivalent plastic. The phantom size, 61 cm high and 30 cm in diameter, was chosen to approximate the human torso and to match the dimensions of cylindrical phantoms used by previous calculations. Holes were drilled down through the phantom to accommodate small tissue equivalent proportional counters (TEPCs) at various depths in the phantom. These counters were used to measure the neutron dose inside the phantom when it was exposed to various sources of neutrons. The holes in the phantom could also accommodate miniature Geiger-Mueller detectors to measure the gamma component of the dose. Neutron and gamma dose profiles were measured for two different sources of neutrons: an unmoderated /sup 252/Cf source and a 733-keV neutron beam generated by a Van de Graaff accelerator. 14 refs., 13 figs., 11 tabs.
- Research Organization:
- Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 6061824
- Report Number(s):
- PNL-6913; ON: DE89013873
- Resource Relation:
- Other Information: Portions of this document are illegible in microfiche products
- Country of Publication:
- United States
- Language:
- English
Similar Records
Angular dependence of the components of dose to the bone marrow and abdomen in a human phantom from 2.95-MeV neutrons
Upgrade of the PNNL TEPC and Multisphere Spectrometer
Related Subjects
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
DEPTH DOSE DISTRIBUTIONS
EVALUATION
NEUTRON DOSIMETRY
MATHEMATICAL MODELS
COMPILED DATA
DOSE EQUIVALENTS
DOSE RATES
LET
NEUTRONS
PHANTOMS
RADIOBIOLOGY
RBE
BARYONS
BIOLOGY
DATA
DOSIMETRY
ELEMENTARY PARTICLES
ENERGY TRANSFER
FERMIONS
HADRONS
INFORMATION
MOCKUP
NUCLEONS
NUMERICAL DATA
RADIATION DOSE DISTRIBUTIONS
SPATIAL DOSE DISTRIBUTIONS
STRUCTURAL MODELS
655003* - Medical Physics- Dosimetry
560151 - Radiation Effects on Animals- Man