Title: RELAP5/MOD2 assessment using semiscale experiments S-NH-1 and S-LH-2

Technical Report ·
DOI:https://doi.org/10.2172/6045737· OSTI ID:6045737

This report presents the results of the RELAP5/MOD2 posttest assessment utilizing two small break loss-of-coolant accident (LOCA) tests (S-NH-1 and S-LH-2) which were performed in the Semiscale Mod-2C facility. Test S-NH-1 was a 0.5% small break LOCA where the high-pressure injection system (HPIS) was inoperable throughout the transient. Test S-LH-2 was a 5% small break LOCA involving a relatively high upper-head-to-downcomer initial bypass flow and nominal emergency core cooling. Through comparisons between data and best-estimate RELAP5 calculations, the capabilities of RELAP5 to calculate the transient phenomena are assessed. For S-NH-1, emphasis was placed on the capability of the code to calculate various operator actions to initiate core heatup in the absence of HPIS. For S-LH-2, the capability of the code to calculate basic small break system response, such as vessel level during loop seal formation and clearing, break uncovery, and primary pressure response following accumulator injection, was assessed. 10 refs., 76 figs., 4 tabs.

Research Organization:
EG and G Idaho, Inc., Idaho Falls, ID (United States)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
6045737
Report Number(s):
NUREG/CR-5010; EGG-2520; ON: TI88002541
Country of Publication:
United States
Language:
English