Safety Evaluation Report Restart of K-Reactor Savannah River Site
In April 1991, the Department of Energy (DOE) issued DOE/DP-0084T, Safety Evaluation Report Restart of K-Reactor Savannah River Site.'' The Safety Evaluation Report (SER) documents the results of DOE reviews and evaluations of the programmatic aspects of a large number of issues necessary to be satisfactorily addressed before restart. The issues were evaluated for compliance with the restart criteria included in the SER. The results of those evaluations determined that the restart criteria had been satisfied for some of the issues. However, for most of the issues at least part of the applicable restart criteria had not been found to be satisfied at the time the evaluations were prepared. For those issues, open or confirmatory items were identified that required resolution. In August 1991, DOE issued DOE/DP-0090T, Safety Evaluation Report Restart of K-Reactor Savannah River Site Supplement 1.'' That document was the first Supplement to the April 1991 SER, and documented the resolution of 62 of the open items identified in the SER. This document is the second Supplement to the April 1991 SER. This second SER Supplement documents the resolution of additional open times identified in the SER, and includes a complete list of all remaining SER open items. The resolution of those remaining open items will be documented in future SER Supplements. Resolution of all open items for an issue indicates that its associated restart criteria have been satisfied, and that DOE concludes that the programmatic aspects of the issue have been satisfactorily addressed.
- Research Organization:
- USDOE Assistant Secretary for Defense Programs, Washington, DC (United States). Office of the Deputy Assistant Secretary for Facilities
- Sponsoring Organization:
- USDOE; USDOE, Washington, DC (United States)
- OSTI ID:
- 6017168
- Report Number(s):
- DOE/DP-0091T; ON: DE92001854
- Country of Publication:
- United States
- Language:
- English
Similar Records
Restart of K-Reactor, Savannah River Site: Safety evaluation report
Record of Decision; Continued operation of K, L, and P Reactors, Savannah River Site, Aiken, South Carolina
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
K REACTOR
REACTOR START-UP
EMERGENCY PLANS
MANAGEMENT
REACTOR SAFETY
SAFETY REPORTS
HEAVY WATER MODERATED REACTORS
OPERATION
PRODUCTION REACTORS
REACTOR OPERATION
REACTORS
SAFETY
SPECIAL PRODUCTION REACTORS
START-UP
220900* - Nuclear Reactor Technology- Reactor Safety
220600 - Nuclear Reactor Technology- Research
Test & Experimental Reactors