skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Evaluation of the second hot dry rock geothermal energy reservoir: results of Phase I, Run Segment 5

Technical Report ·
DOI:https://doi.org/10.2172/5984399· OSTI ID:5984399

The results of a long-term (286 day) flow test of the second hot dry rock reservoir at the Fenton Hill field site are presented. This second reservoir was created by fracturing an interval of granitic rock located at a depth of 2.93 km (9620 ft) in the same wellbore pair used in the creation of the first, smaller reservoir. The new fracture system has a vertical extent of at least 320 m (1050 ft), suggesting that the combined heat-transfer area of the old and new fracture systems is much greater than that of the old system. The virgin rock temperature at the bottom of the deeper interval was 197/sup 0/C (386/sup 0/F). Downhole measurements of the water temperature at the reservoir outlet, as well as temperatures inferred from geothermometry, showed that the thermal drawdown of the reservoir was about 8/sup 0/C, and preliminary estimates indicate that the minimum effective heat-transfer area of the new reservoir is 45,000 m/sup 2/ (480,000 ft/sup 2/), which is six times larger than the first reservoir.

Research Organization:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
5984399
Report Number(s):
LA-8940-HDR; ON: DE82002520
Country of Publication:
United States
Language:
English