The sampling and analysis of the hydrogen rich atmosphere of the 49 EPICOR II ion-exchange prefilter liners generated in the decontamination of radioactive water at TMI-2 will provide data to ensure safe storage and shipment of highly loaded ion-exchange media. This report discusses the prototype gas sampling tool used to breech the containment of the liners, the tool support equipment for sampling and inerting the liners, and the characterization program used for determining the radiolytic hydrogen generation rates in the liners.

Research Organization:
General Public Utilities Nuclear Corp., Middletown, PA (USA)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
5977197
Report Number(s):
GEND-029; ON: DE83015920
Country of Publication:
United States
Language:
English