Theoretical studies on the beam position measurement with button-type pickups in APS
The response of electrostatic button-type pickups for the measurement of the transverse position of charged particle beams was investigated and analytical formulae were obtained for the signal as a function of time t and the coordinates of the beam and the electrodes. The study was done for beam pipes of circular and elliptic cross sections, for rectangular and nonrectangular electrodes, and for several cases of longitudinal beam profiles. The numerical results show good agreement with the analytical results, except that the presence of the photon beam channel and the antechamber causes finite offset ({approximately}20 {mu}m) of the electrical center in the horizontal direction. Time domain analysis indicates that the error in the measurement of the beam position using circular electrodes as compared to rectangular ones was found to be less than 100 {mu}m per 1 cm of beam excursion from the center of the beam pipe for the case of APS storage ring vacuum chamber. 5 refs., 4 figs.
- Research Organization:
- Argonne National Lab., IL (USA)
- Sponsoring Organization:
- USDOE; USDOE, Washington, DC (USA)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 5936288
- Report Number(s):
- ANL/CP-73051; CONF-910505-46; ON: DE91011998
- Resource Relation:
- Conference: 1991 Institute of Electrical and Electronics Engineers (IEEE) particle accelerator conference (PAC), San Francisco, CA (USA), 6-9 May 1991
- Country of Publication:
- United States
- Language:
- English
Similar Records
Analysis of the beam position measurement with button-type pickups in APS
Optimization of four-button beam position monitor configuration for small-gap vacuum chambers