Title: Experimental and calculational results from the Spent Fuel Test-Climax

Abstract

The Spent Fuel Test-Climax (SFT-C) is being conducted under the technical direction of the Lawrence Livermore National Laboratory for the US Department of Energy. The SFT-C is located 420 m below surface in the Climax placed in test storage in April and May 1980. At the same time, 6 electrical elevated-temperature phase of the test. Data related to heat transfer, thermomechanical response, radiation dose, and radiation damage have been collected and are presented here, as appropriate, with calculational results. In general, measured and calculated results compare well.

Authors:
; ;
Publication Date:
Research Org.:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
OSTI Identifier:
59265
Report Number(s):
UCRL-88254; CONF-8210101-2
ON: DE83004217
DOE Contract Number:  
W-7405-ENG-48
Resource Type:
Conference
Resource Relation:
Conference: Workshop on in situ experiments in granite associated with geological disposal of radioactive waste, Stockholm (Sweden), 25-27 Oct 1982; Other Information: DN: Portions of document are illegible; PBD: 14 Oct 1982
Country of Publication:
United States
Language:
English
Subject:
05 NUCLEAR FUELS; 58 GEOSCIENCES; NEVADA TEST SITE; SPENT FUEL STORAGE; GRANITES; HEAT TRANSFER; RADIATION EFFECTS; TEMPERATURE EFFECTS; RADIATION DOSES; TEMPERATURE MEASUREMENT; GEOLOGIC DEPOSITS; RADIOACTIVE WASTE DISPOSAL; Yucca Mountain Project

Citation Formats

Patrick, W C, Ramspott, L D, and Ballou, L B. Experimental and calculational results from the Spent Fuel Test-Climax. United States: N. p., 1982. Web.
Patrick, W C, Ramspott, L D, & Ballou, L B. Experimental and calculational results from the Spent Fuel Test-Climax. United States.
Patrick, W C, Ramspott, L D, and Ballou, L B. 1982. "Experimental and calculational results from the Spent Fuel Test-Climax". United States. https://www.osti.gov/servlets/purl/59265.
@article{osti_59265,
title = {Experimental and calculational results from the Spent Fuel Test-Climax},
author = {Patrick, W C and Ramspott, L D and Ballou, L B},
abstractNote = {The Spent Fuel Test-Climax (SFT-C) is being conducted under the technical direction of the Lawrence Livermore National Laboratory for the US Department of Energy. The SFT-C is located 420 m below surface in the Climax placed in test storage in April and May 1980. At the same time, 6 electrical elevated-temperature phase of the test. Data related to heat transfer, thermomechanical response, radiation dose, and radiation damage have been collected and are presented here, as appropriate, with calculational results. In general, measured and calculated results compare well.},
doi = {},
url = {https://www.osti.gov/biblio/59265}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Oct 14 00:00:00 EDT 1982},
month = {Thu Oct 14 00:00:00 EDT 1982}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: