Title: Performance of an active/passive hybrid solar system utilizing vapor transport

Technical Report ·
DOI:https://doi.org/10.2172/5919073· OSTI ID:5919073

Vapor-phase heat-transport systems are being tested in two of the passive test cells at Los Alamos. The systems consist of an active fin-and-tube collector and a condenser inside a water storage tank. The refrigerant, R-11, can be returned to the collector with a pump or with a self-pumping scheme. A computer model was developed to predict the behavior of the system, after which the computer was used to predict the annual performance of these systems in five cities. The report compares the measured and the predicted results as well as the system's sensitivity to several parameters.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
5919073
Report Number(s):
LA-UR-84-2003; ON: DE85008627
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products
Country of Publication:
United States
Language:
English