skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: System transient response to loss of off-site power

Conference ·
OSTI ID:5890784

A simultaneous trip of the reactor, main circulation pumps, secondary coolant pumps, and pressurizer pump due to loss of off-site power at the High Flux Isotope Reactor (HFIR) located at the Oak Ridge National Laboratory (ORNL) has been analyzed to estimate available safety margin. A computer model based on the Modular Modeling System code has been used to calculate the transient response of the system. The reactor depressurizes from 482.7 psia down to about 23 psia in about 50 seconds and remains stable thereafter. Available safety margin has been estimated in terms of the incipient boiling heat flux ratio. It is a conservative estimate due to assumed less than available primary and secondary flows and higher than normal depressurization rate. The ratio indicates no incipient boiling conditions at the hot spot. No potential damage to the fuel is likely to occur during this transient. 2 refs., 6 figs.

Research Organization:
Oak Ridge National Lab., TN (USA)
Sponsoring Organization:
USDOE; USDOE, Washington, DC (USA)
DOE Contract Number:
AC05-84OR21400
OSTI ID:
5890784
Report Number(s):
CONF-901228-2; ON: DE91011367
Resource Relation:
Conference: 6. Miami international symposium on heat and mass transfer, Miami, FL (USA), 10-12 Dec 1990
Country of Publication:
United States
Language:
English