Conceptual design of the high-flux VTA-2 test assembly for FMIT
This report describes the conceptual design of the test module for the high neutron flux vertical test assembly (VTA-2). The description emphasizes the thermal control systems available for monitoring test specimen temperatures at any desired temperature within the range of 100 to 650/sup 0/C. VTA-2 will be located in the Fusion Materials Irradiation Test Facility (FMIT) test cell directly behind VTA-1.
- Research Organization:
- Hanford Engineering Development Lab., Richland, WA (United States)
- DOE Contract Number:
- AC06-76FF02170
- OSTI ID:
- 5879421
- Report Number(s):
- HEDL-TME-83-19; ON: DE83017022
- Country of Publication:
- United States
- Language:
- English