skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Solid state track recorder neutron dosimetry measurements for fuel debris assessment of TMI-2 demineralizer-A

Technical Report ·
DOI:https://doi.org/10.2172/5867893· OSTI ID:5867893

Solid State Track Recorder (SSTR) neutron dosimetry measurements have been made in TMI-2 makeup Demineralizer A Cubicle in order to assess the amount of fuel debris present by means of the specific neutron activity of TMI-2 fuel. Based on recent calibration data and the results of the TMI-2 SSTR neutron dosimetry, the amount of fuel present is estimated to be 1.7 +- 0.6 kg. This value is in excellent agreement with a value determined independently by Compton recoil gamma-ray spectrometry. Sources of uncertainty in and proposed refinements of the present SSTR measurements are discussed.

Research Organization:
Hanford Engineering Development Lab., Richland, WA (United States)
DOE Contract Number:
AC06-76FF02170
OSTI ID:
5867893
Report Number(s):
HEDL-SA-2834-FP; ON: DE83017004
Resource Relation:
Other Information: Portions are illegible in microfiche products
Country of Publication:
United States
Language: