Title: Response of the SPND measurement system to temperature during the Three Mile Island Unit 2 accident. [Self-Powered Neutron Detector]

Technical Report ·
DOI:https://doi.org/10.2172/5816733· OSTI ID:5816733

The Self-Powered Neutron Detector (SPND) Measuring System is evaluated to determine its ability to indicate temperatures of the fuel rods in the TMI-2 reactor core during the accident. It is concluded for the following reasons that the SPND Measuring System did not provide fuel rod temperatures during the accident: the heat transfer characteristics vary over a range of five octaves; within the range of 1200 to 1800/sup 0/F, the SPND responds to temperature from convection radiation from the fuel rods and self-heating from the gamma flux; within the range of 1200 to 1800/sup 0/F, the signal cable introduces masking signals that are a function of gamma heating, integrated temperature over the cable, and core water level velocity; the data system's worst-case signal-to-noise ratio from aliasing is 0dB; and the recorder system's worst-case signal-to-noise ratio from aliasing is -24dB.