skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: 3D Atlas vertical plate oil transmission line field calculations. Final report

Technical Report ·
DOI:https://doi.org/10.2172/569141· OSTI ID:569141

Because of questions regarding current density and inductance estimates of the Atlas oil transmission line in the region where the vertical plates connect to the disk line, calculations using the 3D FE program Flux3d were initiated. Flux3d inductance values are nearly that estimated by D. Scudder. Calculations for three base designs of E. Ballard and D. Pierce were completed where several variations for each base design were used to determine the important parameters affecting inductance and to check inductance consistency. Flux3d showed for the first base design a very high current density of 36MA/m at the connection between the vertical and horizontal ground plates resulting in a magnetic pressure of 120 kpsi. The second base design modified this connection to reduce the current density to 20MA/m and 36 kpsi and for design 3 current density is 17MA/m. Maximum current density on the hot plates is 20MA/m for all 3 designs. These values assumed 1.2MA per VTL or 45.6MA total system current. Electrical fields on the top of the hot plate near the disk line connection is about 50% greater than the nominal value near the center of the vertical plates.

Research Organization:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sumner Associates, Santa Fe, NM (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
569141
Report Number(s):
LA-SUB-97-54; ON: DE98003066; TRN: AHC29805%%166
Resource Relation:
Other Information: PBD: 18 Sep 1997
Country of Publication:
United States
Language:
English