The Main Injector project at Fermilab requires a dipole with good field quality from 0.1 T to 1.73 T with ramps to full field at up to 2.4 T/s over an aperture of 10 {times} 5 cm. Operation of this magnet for the variety of purposes proposed for the Main Injector results in a design with low inductance, large copper cross section, and field uniformity sufficient for high intensity injection and efficient slow resonant extraction. The resulting design is presented, along with measurement results of a prototype magnet emphasizing the field uniformity. 6 refs., 4 figs., 2 tabs.
- Research Organization:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE; USDOE, Washington, DC (USA)
- DOE Contract Number:
- AC02-76CH03000
- OSTI ID:
- 5676625
- Report Number(s):
- FNAL/C-91/127; CONF-910505-287; ON: DE91014148; TRN: 91-018843
- Resource Relation:
- Conference: 1991 Institute of Electrical and Electronics Engineers (IEEE) particle accelerator conference (PAC), San Francisco, CA (USA), 6-9 May 1991
- Country of Publication:
- United States
- Language:
- English
Similar Records
The Fermilab main injector dipole construction techniques and prototype magnet measurements
The Fermilab Main Injector Dipole construction techniques and prototype magnet measurements
The design and manufacture of the Fermilab Main Injector Dipole Magnet
Conference
·
Sun Sep 01 00:00:00 EDT 1991
·
OSTI ID:5676625
+23 more
The Fermilab Main Injector Dipole construction techniques and prototype magnet measurements
Conference
·
Wed Jan 01 00:00:00 EST 1992
· IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States)
·
OSTI ID:5676625
+7 more
The design and manufacture of the Fermilab Main Injector Dipole Magnet
Conference
·
Sun Mar 01 00:00:00 EST 1992
·
OSTI ID:5676625
+1 more