Title: Error message recording and reporting in the SLC control system

Abstract

Error or information messages that are signaled by control software either in the VAX host computer or the local microprocessor clusters are handled by a dedicated VAX process (PARANOIA). Messages are recorded on disk for further analysis and displayed at the appropriate console. Another VAX process (ERRLOG) can be used to sort, list and histogram various categories of messages. The functions performed by these processes and the algorithms used are discussed.

Authors:
; ; ;
Publication Date:
Research Org.:
Stanford Linear Accelerator Center, CA (USA)
OSTI Identifier:
5659442
Report Number(s):
SLAC-PUB-3633; CONF-850504-84
ON: DE85013057
DOE Contract Number:  
AC03-76SF00515
Resource Type:
Conference
Resource Relation:
Conference: Particle accelerator conference, Vancouver, Canada, 13 May 1985
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; COMMUNICATIONS; COMPUTER CODES; P CODES; COMPUTERIZED CONTROL SYSTEMS; STANFORD LINEAR COLLIDER; ERRORS; RECORDING SYSTEMS; ACCELERATOR FACILITIES; ACCELERATORS; CONTROL SYSTEMS; LINEAR ACCELERATORS; 430303* - Particle Accelerators- Experimental Facilities & Equipment

Citation Formats

Spencer, N, Bogart, J, Phinney, N, and Thompson, K. Error message recording and reporting in the SLC control system. United States: N. p., 1985. Web.
Spencer, N, Bogart, J, Phinney, N, & Thompson, K. Error message recording and reporting in the SLC control system. United States.
Spencer, N, Bogart, J, Phinney, N, and Thompson, K. 1985. "Error message recording and reporting in the SLC control system". United States. https://www.osti.gov/servlets/purl/5659442.
@article{osti_5659442,
title = {Error message recording and reporting in the SLC control system},
author = {Spencer, N and Bogart, J and Phinney, N and Thompson, K},
abstractNote = {Error or information messages that are signaled by control software either in the VAX host computer or the local microprocessor clusters are handled by a dedicated VAX process (PARANOIA). Messages are recorded on disk for further analysis and displayed at the appropriate console. Another VAX process (ERRLOG) can be used to sort, list and histogram various categories of messages. The functions performed by these processes and the algorithms used are discussed.},
doi = {},
url = {https://www.osti.gov/biblio/5659442}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Apr 01 00:00:00 EST 1985},
month = {Mon Apr 01 00:00:00 EST 1985}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: