skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Additional cooling and heating load improvements in seasonal performance modeling of room and central air conditioners and heat pumps. Topical report, Subtask 3. 2

Technical Report ·
DOI:https://doi.org/10.2172/5551797· OSTI ID:5551797

The study focuses on improving the load modeling technique of Seasonal Performance Model (SPM) in order to estimate a more realistic load for seasonal analysis calculations on an hourly basis. A computer simulation program, Seasonal Performance Model Load (SPMLD), was used to calculate the cooling and heating loads for a typical residence in Caribou, Maine; Columbia, Missouri; and Fort Worth, Texas. The derivation of the SPMLD is described and changes made to improve cooling and heating load estimates are identified. (MCW)

Research Organization:
Science Applications, Inc., La Jolla, CA (United States)
DOE Contract Number:
AC04-79AL10757
OSTI ID:
5551797
Report Number(s):
SAI-444-80-311-LJ; ON: DE82003826
Country of Publication:
United States
Language:
English