Passive equilibrium studies on ZT-P
The poloidal field system of ZT-P was modified by the addition of a transformer, which coupled the magnetizing and equilibrium circuits. ZT-P is a small, air core, Reversed Field Pinch, operated at the Los Alamos National Laboratory. It is used as test bed for the much larger ZT-H, RFP experiment, now under construction at LANL. Planned experiments include size scaling measurements and determining the effect of low time constant measurements and determining the effect of low time constant shell operation. ZT-P has had an entirely passive equilibrium system, which did not provide a well centered equilibrium, although a tolerable equilibrium was realized by removing half of the equilibrium coil set. The transformer was added to the poloidal field system to adjust the equilibrium current for a centered plasma, while using the entire coil set. It also had the effect of reducing the dependence of the equilibrium on the plasma resistance. Stable, well centered discharges were achieved over a broad range of plasma currents. The improved equilibrium also lowered the loop voltage and extended the discharge lifetime. These experiments also investigated the unique problems of equilibrium systems on air core RFP devices. 26 refs., 6 figs.
- Research Organization:
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 5504979
- Report Number(s):
- LA-11175-MS; ON: DE88005074
- Country of Publication:
- United States
- Language:
- English
Similar Records
Equilibrium poloidal field distributions in reversed-field-pinch toroidal discharges
Refueling and density control in the ZT-40M reversed field pinch