Technical evaluation of the electrical, instrumentation, and control design aspects of the override of containment purge valve isolation and other engineered safety feature signals for the Fort Calhoun Nuclear Power Plant
This report documents the technical evaluation of the electrical, instrumentation, and control design aspects of the override of containment purge valve isolation and other engineered safety feature signals for the Fort Calhoun nuclear power plant. The review criteria are based on IEEE Std-279-1971 requirements for the safety signals to all purge and ventilation isolation valves. This report is supplied as part of the Selected Electrical, Instrumentation, and Control Systems Issues Program being conducted for the US Nuclear Regulatory Commission by Lawrence Livermore Laboratory.
- Research Organization:
- EG and G, Inc., San Ramon, CA (USA). Energy Measurements Group
- DOE Contract Number:
- EY-76-C-08-1183
- OSTI ID:
- 5495224
- Report Number(s):
- UCRL-15172; TRN: 80-005634
- Country of Publication:
- United States
- Language:
- English
Similar Records
Technical evaluation of the electrical, instrumentation, and control design aspects of the override of containment purge valve isolation and other engineered safety feature signals for the Point Beach Nuclear Power Station, Units 1 and 2
Technical evaluation of the electrical, instrumentation, and control design aspects of the override of containment purge valve isolation and other engineered safety feature signals for the Joseph M. Farley Nuclear Power Plant
Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach Nuclear Power Plant, Units 1 and 2
Technical Report
·
Sat Sep 01 00:00:00 EDT 1979
·
OSTI ID:5495224
Technical evaluation of the electrical, instrumentation, and control design aspects of the override of containment purge valve isolation and other engineered safety feature signals for the Joseph M. Farley Nuclear Power Plant
Technical Report
·
Thu Nov 01 00:00:00 EST 1979
·
OSTI ID:5495224
Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach Nuclear Power Plant, Units 1 and 2
Technical Report
·
Thu Mar 01 00:00:00 EST 1979
·
OSTI ID:5495224
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
CALHOUN-1 REACTOR
ELECTRICAL EQUIPMENT
REACTOR INSTRUMENTATION
ENGINEERED SAFETY SYSTEMS
SPECIFICATIONS
ENRICHED URANIUM REACTORS
EQUIPMENT
POWER REACTORS
PWR TYPE REACTORS
REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200* - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled
CALHOUN-1 REACTOR
ELECTRICAL EQUIPMENT
REACTOR INSTRUMENTATION
ENGINEERED SAFETY SYSTEMS
SPECIFICATIONS
ENRICHED URANIUM REACTORS
EQUIPMENT
POWER REACTORS
PWR TYPE REACTORS
REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200* - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled