skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Fuel cleanup system for the tritium systems test assembly: design and experiments

Conference ·

A major subsystem of the Tritium Systems Test Assembly is the Fuel Cleanup System (FCU) whose functons are to: (1) remove impurities in the form of argon and tritiated methane, water, and ammonia from the reactor exhaust stream and (2) recover tritium for reuse from the tritiated impurities. To do this, a hybrid cleanup system has been designed which utilizes and will test concurrently two differing technologies - one based on disposable, hot metal (U and Ti) getter beds and a second based on regenerable cryogenic asdorption beds followed by catalytic oxidation of impurities to DTO and stackable gases and freezout of the resultant DTO to recover essentially all tritium for reuse.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
5466548
Report Number(s):
LA-UR-80-1273; CONF-800427-8; TRN: 80-009254
Resource Relation:
Journal Volume: 31; Journal Issue: 8; Conference: Tritium technology in fission, fusion, and isotopic application, Dayton, OH, USA, 29 Apr 1980
Country of Publication:
United States
Language:
English