As part of TASTEX related programs two independent methods have been evaluated for the purpose of providing verification of the amount of Pu charged to the head-end of a nuclear fuel processing plant. The first is the Pu/U (gravimetric method), TASTEX Task-L, and the second is the Tracer Method, designated Task-M. Summaries of the basic technology, results of various studies under actual plant conditions, future requirements, are given for each of the Tasks.