Title: Amp-hour counting charge control for photovoltaic hybrid power systems

Abstract

An amp-hour counting battery charge control algorithm has been defined and tested using the Digital Solar Technologies MPR-9400 microprocessor based photovoltaic hybrid charge controller. This work included extensive laboratory and field testing of the charge algorithm on vented lead-antimony and valve regulated lead-acid batteries. The test results have shown that with proper setup amp-hour counting charge control is more effective than conventional voltage regulated sub-array shedding in returning the lead-acid battery to a high state of charge.

Authors:
 [1];  [2]
  1. Sandia National Labs., Albuquerque, NM (United States)
  2. Biri Systems, Ithaca, NY (United States)
Publication Date:
Research Org.:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Org.:
USDOE Assistant Secretary for Energy Efficiency and Renewable Energy, Washington, DC (United States)
OSTI Identifier:
537319
Report Number(s):
SAND-97-2456C; CONF-970953-
ON: DE98000558; TRN: AHC29722%%84
DOE Contract Number:  
AC04-94AL85000
Resource Type:
Conference
Resource Relation:
Conference: 26. IEEE photovoltaic specialists conference, Anaheim, CA (United States), 29 Sep - 3 Oct 1997; Other Information: PBD: [1997]
Country of Publication:
United States
Language:
English
Subject:
14 SOLAR ENERGY; 25 ENERGY STORAGE; PHOTOVOLTAIC POWER SUPPLIES; BATTERY CHARGING; ELECTRIC BATTERIES; HYBRID SYSTEMS; PERFORMANCE; BATTERY CHARGERS; CONTROL SYSTEMS

Citation Formats

Hund, T D, and Thompson, B. Amp-hour counting charge control for photovoltaic hybrid power systems. United States: N. p., 1997. Web.
Hund, T D, & Thompson, B. Amp-hour counting charge control for photovoltaic hybrid power systems. United States.
Hund, T D, and Thompson, B. 1997. "Amp-hour counting charge control for photovoltaic hybrid power systems". United States. https://www.osti.gov/servlets/purl/537319.
@article{osti_537319,
title = {Amp-hour counting charge control for photovoltaic hybrid power systems},
author = {Hund, T D and Thompson, B},
abstractNote = {An amp-hour counting battery charge control algorithm has been defined and tested using the Digital Solar Technologies MPR-9400 microprocessor based photovoltaic hybrid charge controller. This work included extensive laboratory and field testing of the charge algorithm on vented lead-antimony and valve regulated lead-acid batteries. The test results have shown that with proper setup amp-hour counting charge control is more effective than conventional voltage regulated sub-array shedding in returning the lead-acid battery to a high state of charge.},
doi = {},
url = {https://www.osti.gov/biblio/537319}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Oct 01 00:00:00 EDT 1997},
month = {Wed Oct 01 00:00:00 EDT 1997}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: