Title: Siting-selection study for the Soyland Power Cooperative, Inc. , compressed-air energy-storage system (CAES)

Technical Report ·
DOI:https://doi.org/10.2172/5328133· OSTI ID:5328133

A method used for siting a compressed air energy storage (CAES) system using geotechnical and environmental criteria is explained using the siting of a proposed 220 MW water-compensated CAES plant in Illinois as an example. Information is included on the identification and comparative ranking of 28 geotechnically and environmental sites in Illinois, the examination of fatal flaws, e.g., mitigation, intensive studies, costly studies, permit denials, at 7 sites; and the selection of 3 sites for further geological surveying. (LCL)

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
5328133
Report Number(s):
PNL-4078; ON: DE82008766
Resource Relation:
Other Information: Portions of document are illegible. MN only
Country of Publication:
United States
Language:
English