Title: Industrial cogeneration case study No. 2: American Cyanamid Chemical Company, Bound Brook, New Jersey

Technical Report ·
DOI:https://doi.org/10.2172/5317783· OSTI ID:5317783

Within a project for evaluating the economics of cogeneration for industrial plants with an electrical capacity of 10,000 to 30,000 kW, the American Cyanamid plant at Bound Brook, NJ was selected for study. Built between 1915 and 1920 this power plant was converted in the 1960's from coal-fueling to oil and natural gas. Information is presented on the plant site, fuel usage, generation costs, comparative cost of purchasable electric power, equipment used, performance, and reliability and capital and maintenance costs. (LCL)

Research Organization:
Faucett (Jack) Associates, Inc., Chevy Chase, MD (USA)
DOE Contract Number:
W-31-109-ENG-38
OSTI ID:
5317783
Report Number(s):
ANL/CNSV-TM-37
Country of Publication:
United States
Language:
English