Title: Summary of transient high-voltage calculations for the FRX-C experiment

Technical Report ·
DOI:https://doi.org/10.2172/5256855· OSTI ID:5256855

Calculations of the electrical circuit equations are performed over a wide range of parameters corresponding to the FRX-C field-reversed THETA-pinch experiment at Los Alamos. Without any plasma or external damping, serious voltage doubling and quadrupling of the main capacitor bank charge voltage are observed. These oscillating high voltages are found to be adequately suppressed by the strategic placement of external snubber circuitry. On the other hand, no doubling of the THETA-pinch preionization bank charge voltage is found. Calculations of the equations for the z-pinch preionization circuit are also performed.

Research Organization:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
5256855
Report Number(s):
LA-9380-MS; ON: DE82019707
Resource Relation:
Other Information: Portions of document are illegible
Country of Publication:
United States