Title: Prototype steam generator test at SCTI/ETEC. Acoustic program test plan. [LMFBR]

Technical Report ·
DOI:https://doi.org/10.2172/5238432· OSTI ID:5238432

This document is an integrated test plan covering programs at General Electric (ARSD), Rockwell International (RI) and Argonne National Laboratory (CT). It provides an overview of the acoustic leak detection test program which will be completed in conjunction with the prototype LMFBR steam generator at the Energy Technology Engineering Laboratory. The steam generator is installed in the Sodium Components Test Installation (SCTI). Two acoustic detection systems will be used during the test program, a low frequency system developed by GE-ARSD (GAAD system) and a high frequency system developed by RI-AI (HALD system). These systems will be used to acquire data on background noise during the thermal-hydraulic test program. Injection devices were installed during fabrication of the prototype steam generator to provide localized noise sources in the active region of the tube bundle. These injectors will be operated during the steam generator test program, and it will be shown that they are detected by the acoustic systems.

Research Organization:
General Electric Co., Sunnyvale, CA (USA). Advanced Reactor Systems Dept.
DOE Contract Number:
AT03-76SF70030
OSTI ID:
5238432
Report Number(s):
DOE/SF/70030-T60; XL-791-10141; ON: DE82008075; TRN: 82-015805
Resource Relation:
Other Information: Portions of document are illegible
Country of Publication:
United States
Language:
English