In support of Unresolved Safety Issue, USI A-43, Containment emergency Sump Performance, 8 additional nuclear power plants (representative of different US reactor manufacturers and architect-engineers) were surveyed to identify and document the types and amounts of insulation used, location within containment, components insulated, material characteristics, and methods of installation and attachment. These plants were selected to obtain survey information on older plants and supplements information previously reported in NUREG/CR-2403. In addition, a preliminary assessment was made of the potential for migration to the emergency sump of the insulation debris which might be generated as a result of the postulated loss-of-coolant accident (pipe break).

Research Organization:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Burns and Roe, Inc., Oradell, NJ (USA)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-76DP00789
OSTI ID:
5235578
Report Number(s):
NUREG/CR-2403-Suppl.1; SAND-82-0927-Suppl.1; ON: DE82016192; TRN: 82-013446
Resource Relation:
Other Information: Portions of document are illegible