skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Solar Energy System performance evaluation: seasonal report for Colt Pueblo, Pueblo, Colorado

Technical Report ·
DOI:https://doi.org/10.2172/5196768· OSTI ID:5196768

The Colt Pueblo Solar Energy System was designed to provide space heating and hot water preheating for the US Department of Transportation Test Center at Pueblo, Colorado. The system consists of 583 square feet of Colt A-151 series flat plate liquid collectors, a petroleum-base thermal energy transport fluid, an 1100 gallon water-filled solar energy storage tank, pumps, heat exchangers, controls and associated plumbing. Cold water passes through a liquid-to-liquid heat exchanger internal to the solar energy storage tank to preheat the water supplied to a 30 gallon electric hot water tank. A parallel circulation loop also operates to transfer solar generated heat to the hot water tank. Solar Energy System piping is protected from freezing with heat tapes. There are five modes of system operation. (MHR)

Research Organization:
International Business Machines Corp., Huntsville, AL (USA). Federal Systems Div.
DOE Contract Number:
AI01-76CS31037
OSTI ID:
5196768
Report Number(s):
DOE/NASA/CR-161493
Country of Publication:
United States
Language:
English