Title: Monte Carlo calculation of flux-to-dose-rate conversion factors for energies between 0. 01 and 1. 00 MeV

Conference ·
OSTI ID:5185712

Gamma-ray flux-to-dose-rate conversion factors for energies between 0.01 and 1.0 MeV were computed using the Monte Carlo method for a 30-cm-thick slab having the standard-man composition. Agreement between the computed factors and standard factors (ANSI/ANS-6.1.1-1977) was optimal for energies above 0.1 MeV and was at most 30% lower (at 0.02 MeV) for energies below 0.1 MeV. The computed factors were also in agreement with experimentally-obtained factors.

Research Organization:
Oak Ridge National Lab., TN (USA); Denison Univ., Granville, OH (USA)
DOE Contract Number:
W-7405-ENG-26
OSTI ID:
5185712
Report Number(s):
CONF-801282-1; ON: DE82006821; TRN: 82-014432
Resource Relation:
Conference: Seminar on the Monte Carlo method: a solution to radiation transport problems, Oak Ridge, TN, USA, 11 Dec 1980
Country of Publication:
United States
Language:
English