EBT-P gamma-ray shielding system
Abstract
An elaborate study was carried out for the coil and biological shield of the ELMO Bumpy Torus proof-of-principle (EBT-P) device. A three-dimensional scoping study for the coil shield was performed for four different shielding options to define the heat load for each component and check the compliance with the design criterion of 10 watts maximum heat per coil from the gamma ray sources. Also, a detailed biological dose survey was performed which included: (a) the dose equivalent inside and outside the building, (b) the dose equivalent from the two mazes of the machine room, and (c) the skyshine contribution to the dose equivalent.
- Authors:
- Publication Date:
- Research Org.:
- Argonne National Lab. (ANL), Argonne, IL (United States)
- OSTI Identifier:
- 5181678
- Report Number(s):
- ANL/FPP/TM-152
ON: DE82017658; TRN: 82-014646
- DOE Contract Number:
- W-31-109-ENG-38
- Resource Type:
- Technical Report
- Resource Relation:
- Other Information: Portions of document are illegible
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 70 PLASMA PHYSICS AND FUSION TECHNOLOGY; ELMO BUMPY TORUS; GAMMA RADIATION; SHIELDING; DOSE EQUIVALENTS; DESIGN; DOSE RATES; MAGNET COILS; MONTE CARLO METHOD; RADIATION DOSES; THREE-DIMENSIONAL CALCULATIONS; DOSES; ELECTRIC COILS; ELECTRICAL EQUIPMENT; ELECTROMAGNETIC RADIATION; ELMO DEVICES; EQUIPMENT; IONIZING RADIATIONS; MAGNETIC MIRRORS; OPEN PLASMA DEVICES; RADIATIONS; THERMONUCLEAR DEVICES; 700209* - Fusion Power Plant Technology- Component Development & Materials Testing
Citation Formats
Gohar, Y. EBT-P gamma-ray shielding system. United States: N. p., 1981.
Web. doi:10.2172/5181678.
Gohar, Y. EBT-P gamma-ray shielding system. United States. https://doi.org/10.2172/5181678
Gohar, Y. 1981.
"EBT-P gamma-ray shielding system". United States. https://doi.org/10.2172/5181678. https://www.osti.gov/servlets/purl/5181678.
@article{osti_5181678,
title = {EBT-P gamma-ray shielding system},
author = {Gohar, Y},
abstractNote = {An elaborate study was carried out for the coil and biological shield of the ELMO Bumpy Torus proof-of-principle (EBT-P) device. A three-dimensional scoping study for the coil shield was performed for four different shielding options to define the heat load for each component and check the compliance with the design criterion of 10 watts maximum heat per coil from the gamma ray sources. Also, a detailed biological dose survey was performed which included: (a) the dose equivalent inside and outside the building, (b) the dose equivalent from the two mazes of the machine room, and (c) the skyshine contribution to the dose equivalent.},
doi = {10.2172/5181678},
url = {https://www.osti.gov/biblio/5181678},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Dec 01 00:00:00 EST 1981},
month = {Tue Dec 01 00:00:00 EST 1981}
}
Save to My Library