skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Indoor air-quality measurements in energy-efficient residential buildings

Conference ·
OSTI ID:5160048

The potential impact on indoor air quality of energy-conserving measures that reduce ventilation is being assessed in a field-monitoring program conducted by the Lawrence Berkeley Laboratory. Using a mobile laboratory, on-site monitoring of infiltration rate, carbon dioxide, carbon monoxide, nitrogen dioxide, nitric oxide, ozone, sulfur dioxide, formaldehyde, total aldehydes, and particulates was conducted in three houses designed to be energy-efficient. Preliminary results show that energy-conserving design features that reduce air-exchange rates compromise indoor air quality; specifically, indoor levels of several pollutants were found to exceed levels detected outdoors. Although the indoor levels of most pollutants are within limits established by present outdoor air-quality standards, considerable work remains to be accomplished before health-risk effects can be accurately assessed and broad-scale regulatory guidelines revised to comply with energy-conservation goals.

Research Organization:
California Univ., Berkeley (USA). Lawrence Berkeley Lab.
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
5160048
Report Number(s):
LBL-8894(Rev.); CONF-790634-4(Rev.); EEB-Vent-80-8
Resource Relation:
Conference: 72. annual Air Pollution Control Association meeting, Cincinnati, OH, USA, 24 Jun 1979
Country of Publication:
United States
Language:
English