The question raised here is whether the RHIC lattice is robust enough to make all these commissioning manipulations possible. There are of course many factors involved in answering this question in a definitive manner. The purpose of this note is to see if there are any fundamental and serious shortcomings basic to the lattice. The lattice considered here is the one presented to the workshop by Steve Tepikian and called RHIC91. More specifically, we fix nine quadrupole parameters in all insertions except in the 6 o'clock insertion where the independent parameters is sixteen. The so-called perfect matching may require fourteen parameters instead of nine but the difference is insignificant. On the other hand, if the number of parameters is reduced from sixteen to nine in the 6 o'clock insertion, the mismatch in the arc beta function becomes non-trivial. For example, the horizontal beta may vary between 40m to 60m at QF locations.