skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Analysis of scrams and forced outages at boiling water reactors

Technical Report ·
DOI:https://doi.org/10.2172/5108428· OSTI ID:5108428

This report documents the results of a study of scrams and forced outages at General Electric Boiling Water Reactors (BWRs) operating in the United States. This study was conducted for Sandia Laboratories under a Light Water Reactor Safety Program which it manages for the United States Department of Energy. Operating plant data were used to identify the causes of scrams and forced outages. Causes of scrams and forced outages have been summarized as a function of operating plant and plant age and also ranked according to the number of events per year, outage time per year, and outage time per event. From this ranking, identified potential improvement opportunities were evaluated to determine the associated benefits and impact on plant availability.

Research Organization:
General Electric Co., San Jose, CA (United States)
Sponsoring Organization:
USDOE Office of Nuclear Energy (NE)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
5108428
Report Number(s):
ALO-87; NEDG-25202; TRN: 80-016693
Country of Publication:
United States
Language:
English