Title: UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells

Conference ·
OSTI ID:5058

NREL's PV Cell and Module Performance Characterization group has built a new spectral responsivity measurement system for solar cells. It uses a xenon arc lamp source, a single, grating monochrometer, and a fiber-optic bundle to couple the monochromatic light to the test device. The system has a spectral bandwidth of 2 nm, minimum spot diameter of 1.6 mm, a spectral range of 280-1330 nm, and uncertainty better than {+-}3% over most of this range. It is capable of incorporating light bias with intensities exceeding one sun. This paper discusses the system's features, capabilities, calibration, and measurement uncertainties.

Research Organization:
National Renewable Energy Lab. (NREL), Golden, CO (United States)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC36-83CH10093
OSTI ID:
5058
Report Number(s):
NREL/CP-520-25654; ON: DE00005058; TRN: US200306%%244
Resource Relation:
Conference: UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells, Presented at the National Center for Photovoltaics Program Review Meeting, Denver, CO (US), 09/08/1998--09/11/1998; Other Information: PBD: 12 Nov 1998
Country of Publication:
United States
Language:
English

Similar Records

UV-VIS-IR spectral responsivity measurements system for solar cells
Journal Article · Mon Mar 01 00:00:00 EST 1999 · AIP Conference Proceedings · OSTI ID:5058

Photovoltaic spectral responsivity measurements
Conference · Tue Sep 01 00:00:00 EDT 1998 · OSTI ID:5058

Solar cell spectral response measurement errors related to spectral band width and chopped light waveform
Conference · Wed Dec 31 00:00:00 EST 1997 · OSTI ID:5058