H5 fast-kicker-magnet pulser
The fast extraction kicker magnet for the AGS is powered by a novel pulse generator. A pulse forming network (PFN) is discharged into nearly 100% mismatched load. The pulser delivers a current pulse of 3000 amperes peak pulse with a 2% flat-top ripple into a 1.4 ..mu.. H single turn ferrite core magnet. The pulse is 2.8 ..mu..sec wide with a 180 nsec rise time, at a 0.5 to 1.5 pps repetition rate. The pulse rise time is required to provide clean extraction of the 28 GeV proton beam by bringing the kicker magnet field up to 1.25 kG within the 220 nsec space between proton bunches in the machine. The pulser is mounted adjacent to the kicker magnet in the AGS ring. The thyratron's characteristics are not affected by the ionizing radiation environment during operation of the AGS (Alternating Gradient Synchrotron).
- Research Organization:
- Brookhaven National Lab., Upton, NY (USA)
- DOE Contract Number:
- AC02-76CH00016
- OSTI ID:
- 5032639
- Report Number(s):
- BNL-31427; CONF-820626-10; ON: DE82020002
- Resource Relation:
- Conference: 15. power modulator symposium, Baltimore, MD, USA, 14 Jun 1982; Other Information: Portions of document are illegible
- Country of Publication:
- United States
- Language:
- English
Similar Records
Single-bunch kicker pulser
Test fast kicker pulser
Related Subjects
BROOKHAVEN AGS
KICKER MAGNETS
PULSE GENERATORS
DESIGN
ELECTRONIC CIRCUITS
PERFORMANCE
PULSE RISE TIME
ACCELERATORS
CYCLIC ACCELERATORS
ELECTRICAL EQUIPMENT
ELECTROMAGNETS
ELECTRONIC EQUIPMENT
EQUIPMENT
FUNCTION GENERATORS
MAGNETS
SYNCHROTRONS
TIMING PROPERTIES
430302* - Particle Accelerators- Injection & Extraction Systems