skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Failure of latch mechanism for motion control of safety rods

Technical Report ·
DOI:https://doi.org/10.2172/5029243· OSTI ID:5029243

During safety rod tests in K-reactor prior to startup, one safety rod could not be lifted because the button'' broke off and became lodged in the mechanism. Examination of the failed latch assembly along with other assemblies from both K-Area and L-Area revealed several missing buttons as well as severely deformed jaw hanger extensions.'' We participated in the investigation of the damage by request of the Reactor Restart Section. Based on our study of the latch mechanism, the modifications to the safety rod extension,'' and the operating history of the machine, this memorandum describes the causes of the observed damage with experimental evidence and calculations to support the findings. 3 refs.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE; USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
5029243
Report Number(s):
WSRC-RP-92-112; ON: DE92018132
Country of Publication:
United States
Language:
English