The RHIC real time data link system
Abstract
The RHIC Real Time Data Link (RTDL) System distributes to all locations around the RHIC ring machine parameters of general interest to accelerator systems and users. The system, along with supporting host interface, is centrally located. The RTDL System is comprised of two module types: the Encoder Module (V105) and the Input Module (V106). There is only one V105 module, but many (up to 128) Input Modules. Multiple buffered outputs are provided for use locally or for retransmission to other RHIC equipment locations. Machine parameters are generated from the V115 Waveform Generator Module (WFG) or from machine hardware and coupled directly through a fiber optic serial link to one of the V106 input channels.
- Authors:
- Publication Date:
- Research Org.:
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- Sponsoring Org.:
- USDOE Office of Energy Research, Washington, DC (United States)
- OSTI Identifier:
- 495795
- Report Number(s):
- BNL-63942; CONF-970503-100
ON: DE97006676; TRN: 97:013232
- DOE Contract Number:
- AC02-76CH00016
- Resource Type:
- Conference
- Resource Relation:
- Conference: 17. IEEE particle accelerator conference, Vancouver (Canada), 12-16 May 1997; Other Information: PBD: [1997]
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 43 PARTICLE ACCELERATORS; BROOKHAVEN RHIC; DATA TRANSMISSION SYSTEMS; REAL TIME SYSTEMS; COMPUTERIZED CONTROL SYSTEMS; DESIGN
Citation Formats
Hartmann, H. The RHIC real time data link system. United States: N. p., 1997.
Web.
Hartmann, H. The RHIC real time data link system. United States.
Hartmann, H. 1997.
"The RHIC real time data link system". United States. https://www.osti.gov/servlets/purl/495795.
@article{osti_495795,
title = {The RHIC real time data link system},
author = {Hartmann, H},
abstractNote = {The RHIC Real Time Data Link (RTDL) System distributes to all locations around the RHIC ring machine parameters of general interest to accelerator systems and users. The system, along with supporting host interface, is centrally located. The RTDL System is comprised of two module types: the Encoder Module (V105) and the Input Module (V106). There is only one V105 module, but many (up to 128) Input Modules. Multiple buffered outputs are provided for use locally or for retransmission to other RHIC equipment locations. Machine parameters are generated from the V115 Waveform Generator Module (WFG) or from machine hardware and coupled directly through a fiber optic serial link to one of the V106 input channels.},
doi = {},
url = {https://www.osti.gov/biblio/495795},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Jul 01 00:00:00 EDT 1997},
month = {Tue Jul 01 00:00:00 EDT 1997}
}
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.