skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Operating experience and reliability improvements on the 5 kW CW klystron at Jefferson Lab

Conference ·
OSTI ID:489668
;  [1]
  1. Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

With substantial operating hours on the RF system, considerable information on reliability of the 5 kW CW klystrons has been obtained. High early failure rates led to examination of the operating conditions and failure modes. Internal ceramic contamination caused premature failure of gun potting material and ultimate tube demise through arcing or ceramic fracture. A planned course of reporting and reconditioning of approximately 300 klystrons, plus careful attention to operating conditions and periodic analysis of operational data, has substantially reduced the failure rate. It is anticipated that implementation of planned supplemental monitoring systems for the klystrons will allow most catastrophic failures to be avoided. By predicting end of life, tubes can be changed out before they fail, thus minimizing unplanned downtime. Initial tests have also been conducted on this same klystron operated at higher voltages with resultant higher output power. The outcome of these tests will provide information to be considered for future upgrades to the accelerator.

Research Organization:
Southeastern Universities Research Association, Inc., Newport News, VA (United States)
Sponsoring Organization:
USDOE Office of Energy Research, Washington, DC (United States)
DOE Contract Number:
AC05-84ER40150
OSTI ID:
489668
Report Number(s):
DOE/ER/40150-1122; CONF-970503-14; JLAB-ACE-97-01; ON: DE97006531; TRN: 97:012588
Resource Relation:
Conference: 17. IEEE particle accelerator conference, Vancouver (Canada), 12-16 May 1997; Other Information: PBD: 1997
Country of Publication:
United States
Language:
English