Title: Vadose zone monitoring system installation report for McClellan AFB

Abstract

Two vadose zone monitoring systems (VZMS) have been installed at Site S-7, in Investigation Cluster 34 (IC 34), in Operable Unit A (OU A) of McClellan AFB. The two boreholes, VZMS-A and VZMS-B were instrumented at depths ranging from approximately 6 ft to 113 ft. Instruments were installed in clusters using a custom-made stainless steel cage with a spring-loaded mechanism allowing instruments to be in contact with the well bore wall once in place. Each cluster contains a tensiometer, suction lysimeter, soil gas probe and thermistor for measuring hydraulic potential, liquid- and gas-phase pressure, temperature of the formation and for collecting samples for chemical analyses in both the liquid and gas phases. Neutron probe logging is performed in two separate, smaller borings, VZMS-NP-1 and VZMS-NP-2, to obtain soil moisture content data. Preliminary details of soil gas analyses, laboratory field testing of soil samples, particle size analyses and neutron probe data are presented.

Authors:
; ; ; ;
Publication Date:
Research Org.:
Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
Sponsoring Org.:
Department of Defense, Washington, DC (United States)
OSTI Identifier:
471410
Report Number(s):
LBNL-39525
ON: DE97005930; TRN: 97:003124
DOE Contract Number:  
AC03-76SF00098
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 31 Oct 1996
Country of Publication:
United States
Language:
English
Subject:
54 ENVIRONMENTAL SCIENCES; USA; MILITARY FACILITIES; REMEDIAL ACTION; SITE CHARACTERIZATION; ORGANIC COMPOUNDS; ECOLOGICAL CONCENTRATION; SOILS; MONITORING; ENVIRONMENTAL TRANSPORT; VOLATILE MATTER

Citation Formats

Zawislanski, P, Faybishenko, B, James, A, Freifeld, B, and Salve, R. Vadose zone monitoring system installation report for McClellan AFB. United States: N. p., 1996. Web. doi:10.2172/471410.
Zawislanski, P, Faybishenko, B, James, A, Freifeld, B, & Salve, R. Vadose zone monitoring system installation report for McClellan AFB. United States. https://doi.org/10.2172/471410
Zawislanski, P, Faybishenko, B, James, A, Freifeld, B, and Salve, R. 1996. "Vadose zone monitoring system installation report for McClellan AFB". United States. https://doi.org/10.2172/471410. https://www.osti.gov/servlets/purl/471410.
@article{osti_471410,
title = {Vadose zone monitoring system installation report for McClellan AFB},
author = {Zawislanski, P and Faybishenko, B and James, A and Freifeld, B and Salve, R},
abstractNote = {Two vadose zone monitoring systems (VZMS) have been installed at Site S-7, in Investigation Cluster 34 (IC 34), in Operable Unit A (OU A) of McClellan AFB. The two boreholes, VZMS-A and VZMS-B were instrumented at depths ranging from approximately 6 ft to 113 ft. Instruments were installed in clusters using a custom-made stainless steel cage with a spring-loaded mechanism allowing instruments to be in contact with the well bore wall once in place. Each cluster contains a tensiometer, suction lysimeter, soil gas probe and thermistor for measuring hydraulic potential, liquid- and gas-phase pressure, temperature of the formation and for collecting samples for chemical analyses in both the liquid and gas phases. Neutron probe logging is performed in two separate, smaller borings, VZMS-NP-1 and VZMS-NP-2, to obtain soil moisture content data. Preliminary details of soil gas analyses, laboratory field testing of soil samples, particle size analyses and neutron probe data are presented.},
doi = {10.2172/471410},
url = {https://www.osti.gov/biblio/471410}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Oct 31 00:00:00 EST 1996},
month = {Thu Oct 31 00:00:00 EST 1996}
}