CSER 90-006, addendum 1: Criticality safety control for source term reduction project in the scrubber glovebox of Building 232-Z. Revision 1
This Criticality Safety Evaluation Report addendum extends the coverage of the original CSER (90-006) about dismantling the ductwork in 232-Z to include cleanout of the Scrubber Glovebox, with an estimated residual Pu holdup of less than 200 grams. For conservatism and containment considerations, the provisions about waste packaging and water exclusion from the original work are retained, even though it is not credible for the Scrubber Pu content to be made critical with water added (NDA gives about 1/3 a minimum critical mass).
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-87RL10930
- OSTI ID:
- 45561
- Report Number(s):
- WHC-SD-SQA-CSA-20390-Rev.1; ON: DE95009149; TRN: 95:010947
- Resource Relation:
- Other Information: PBD: 10 Mar 1995
- Country of Publication:
- United States
- Language:
- English
Similar Records
Criticality safety control for source term reduction in Scrubber Glovebox of Building 232-Z. CSER 90-006, Addendum 1
Addendum 1 to CSER 97-025: PFP storage of 9.25/9.5 inch tall, 4.4 kg Pu cans on existing Vault 4 pedestals
Resolution of USQ regarding source term in the 232-Z Waste Incinerator Building
Technical Report
·
Tue Feb 21 00:00:00 EST 1995
·
OSTI ID:45561
Addendum 1 to CSER 97-025: PFP storage of 9.25/9.5 inch tall, 4.4 kg Pu cans on existing Vault 4 pedestals
Technical Report
·
Thu Sep 04 00:00:00 EDT 1997
·
OSTI ID:45561
Resolution of USQ regarding source term in the 232-Z Waste Incinerator Building
Conference
·
Fri Sep 01 00:00:00 EDT 1995
·
OSTI ID:45561