Title: Summary of round robin measurements of radiation induced conductivity in Wesgo AL995 alumina

Technical Report ·
DOI:https://doi.org/10.2172/414887· OSTI ID:414887
 [1]
  1. Oak Ridge National Lab., TN (United States)

This existing data on radiation induced conductivity (RIC) measurements performed on the same heat of the IEA reference ceramic insulator are summarized. Six different sets of RIC measurements have been performed on Wesgo AL995 at dose rates between 10 Gy/s and 1 MGy/s. In general, good agreement was obtained between the different groups of researchers. The data indicate that the RIC at a test temperature of 400-500{degrees}C is approximately linear with ionizing dose rate up to {approximately}1000 Gy/s, and exhibits an approximately square root dependence on dose rate between 1 kGy/s and 1 MGy/s.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
OSTI ID:
414887
Report Number(s):
DOE/ER-0313/20; ON: DE97000700; TRN: 97:001406
Resource Relation:
Other Information: PBD: Oct 1996; Related Information: Is Part Of Fusion materials semiannual progress report for the period ending June 30, 1996; PB: 358 p.