Exposure rate response analysis of criticality accident dectector at Savannah River Site
Conference
·
OSTI ID:39663
This analysis investigated the exposure response behavior of gamma-ray ionization chambers used in the criticality accident systems at the Savannah River Site (SRS). The project consisted of performing exposure response measurements with a calibrated {sup 137}Cs source for benchmarking of the MCNP Monte Carlo code. MCNP was then used to extrapolate the ion chamber`s response to gamma-rays with energies outside the current domain of measured data for criticality fission sources.
- Research Organization:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC09-89SR18035
- OSTI ID:
- 39663
- Report Number(s):
- WSRC-MS-94-0544; CONF-950601-2; ON: DE95004801; TRN: 95:009540
- Resource Relation:
- Conference: Annual meeting of the American Nuclear Society (ANS), Philadelphia, PA (United States), 25-29 Jun 1995; Other Information: PBD: [1995]
- Country of Publication:
- United States
- Language:
- English
Similar Records
Exposure rate response analysis of criticality accident detectors at the Savannah River Site
Ultra-low-level measurements of airborne fission products from the Fukushima Daiichi reactor accident using high volume collection systems at Savannah River National Laboratory
Cesium in the Savannah River Site environment
Journal Article
·
Sun Dec 31 00:00:00 EST 1995
· Transactions of the American Nuclear Society
·
OSTI ID:39663
Ultra-low-level measurements of airborne fission products from the Fukushima Daiichi reactor accident using high volume collection systems at Savannah River National Laboratory
Journal Article
·
Wed Nov 30 00:00:00 EST 2022
· Journal of Environmental Radioactivity
·
OSTI ID:39663
+5 more
Cesium in the Savannah River Site environment
Technical Report
·
Sun Mar 01 00:00:00 EST 1992
·
OSTI ID:39663
+4 more