Title: Boxberg III-2 x 500 MW units: Refurbishing and environmental protection measures on the 815 T/H steam generator of works II in Boxberg Power Station

Abstract

The object of the upgrading measures on the steam generators is: (1) To comply with the requirements of the German antipollution law, which imposes a permissible NO{sub x} content in the flue gas of less than 200 Mg/m{sup 3} STP and a CO content of less than 250 Mg/m{sup 3} STP. (2) To increase the boiler efficiency and availability and the efficiency of the water/steam cycle.

Authors:
; ;  [1]
  1. L&C Steinmueller GmbH, Gummersbach (Germany)
Publication Date:
Research Org.:
North Dakota Univ., Grand Forks, ND (United States)
OSTI Identifier:
374632
Report Number(s):
DOE/MC/30097-5161-Pt.2; CONF-9410458-Pt.2
ON: DE96011553; TRN: 96:004422-0058
Resource Type:
Conference
Resource Relation:
Conference: 2. international conference on energy and environment: transitions in East Central Europe, Prague (Czech Republic), 31 Oct - 1 Nov 1994; Other Information: PBD: Dec 1995; Related Information: Is Part Of Advanced power assessment for Czech lignite, Task 3.6, Part 2; Sondreal, E.A.; Mann, M.D.; Weber, G.W.; Young, B.C.; PB: 774 p.
Country of Publication:
United States
Language:
English
Subject:
20 FOSSIL-FUELED POWER PLANTS; STEAM GENERATORS; MODIFICATIONS; BOILERS; EFFICIENCY; BROWN COAL

Citation Formats

Cossman, R, Fritz, M, and Bauchmueller, R. Boxberg III-2 x 500 MW units: Refurbishing and environmental protection measures on the 815 T/H steam generator of works II in Boxberg Power Station. United States: N. p., 1995. Web.
Cossman, R, Fritz, M, & Bauchmueller, R. Boxberg III-2 x 500 MW units: Refurbishing and environmental protection measures on the 815 T/H steam generator of works II in Boxberg Power Station. United States.
Cossman, R, Fritz, M, and Bauchmueller, R. 1995. "Boxberg III-2 x 500 MW units: Refurbishing and environmental protection measures on the 815 T/H steam generator of works II in Boxberg Power Station". United States. https://www.osti.gov/servlets/purl/374632.
@article{osti_374632,
title = {Boxberg III-2 x 500 MW units: Refurbishing and environmental protection measures on the 815 T/H steam generator of works II in Boxberg Power Station},
author = {Cossman, R and Fritz, M and Bauchmueller, R},
abstractNote = {The object of the upgrading measures on the steam generators is: (1) To comply with the requirements of the German antipollution law, which imposes a permissible NO{sub x} content in the flue gas of less than 200 Mg/m{sup 3} STP and a CO content of less than 250 Mg/m{sup 3} STP. (2) To increase the boiler efficiency and availability and the efficiency of the water/steam cycle.},
doi = {},
url = {https://www.osti.gov/biblio/374632}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Dec 01 00:00:00 EST 1995},
month = {Fri Dec 01 00:00:00 EST 1995}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: