Title: 324 Building fire hazards analysis implementation plan

Technical Report ·
DOI:https://doi.org/10.2172/362579· OSTI ID:362579

In March 1998, the 324 Building Fire Hazards Analysis (FHA) (Reference 1) was approved by the US Department of Energy, Richland Operations Office (DOE-RL) for implementation by B and W Hanford Company (BWHC). The purpose of the FHA was to identify gaps in compliance with DOE Order 5480.7A (Reference 2) and Richland Operations Office Implementation Directive (RLID) 5480.7 (Reference 3), especially in regard to loss limitation. The FHA identified compliance gaps in six areas and provided 20 recommendations to bring the 324 Building into compliance with DOE Order 5480.7A. Additionally, one observation was provided. To date, four of the recommendations and the one observation have been completed. Actions identified for seven of the recommendations are currently in progress. Exemption requests will be transmitted to DOE-RL for three of the recommendations. Six of the recommendations are related to future shut down activities of the facility and the corrective actions are not being addressed as part of this plan. The actions for recommendations associated with the safety related part of the 324 Building and operation of the cells and support areas were evaluated using the Unreviewed Safety Question (USQ) process. Major Life Safety Code concerns have been corrected. The status of the recommendations and actions was confirmed during the July 1998 Fire Protection Assessment. BVMC will use this Implementation Plan to bring the 324 Building and its operation into compliance with DOE Order 5480.7A and RLID 5480.7.

Research Organization:
Fluor Daniel Hanford, Inc., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
362579
Report Number(s):
HNF-3235; ON: DE99050771; BR: EW7002010; TRN: AHC29926%%234
Resource Relation:
Other Information: PBD: 16 Sep 1998
Country of Publication:
United States
Language:
English

Similar Records

324 Building fire hazards analysis implementation plan
Technical Report · Mon May 10 00:00:00 EDT 1999 · OSTI ID:362579

327 Building fire hazards analysis implementation plan
Technical Report · Wed Sep 16 00:00:00 EDT 1998 · OSTI ID:362579

327 Building fire hazards analysis implementation plan
Technical Report · Mon May 10 00:00:00 EDT 1999 · OSTI ID:362579