skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Alpha contamination levels in SMF south cell and compartments

Technical Report ·
DOI:https://doi.org/10.2172/353315· OSTI ID:353315

This document describes the detailed contamination survey performed in the Shielded Materials Facility (SMF) South Cell and the four compartments used during the CsCl activities. Smears were obtained at each operating station in South Cell and analyzed at the 325 Building. The smear results indicate that the highest contamination levels are in Compartment 1 and South Cell proper, with significantly lower contamination levels measured in the other three compartments. Although some of the smears indicated the presence of alpha contamination, it will be shown that the source of the alpha contamination was cross-contamination during processing in the 325 Building hot cells and that the SMF is free of alpha contamination. The alpha-free status of South Cell is consistent with process knowledge of previous South Cell activities.

Research Organization:
Fluor Daniel Hanford, Inc., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
353315
Report Number(s):
HNF-2849; ON: DE99050720; BR: EW7050000; TRN: AHC29923%%147
Resource Relation:
Other Information: PBD: 16 Jun 1998
Country of Publication:
United States
Language:
English