Title: Thermal analysis of thermo-gravimetric measurements of spent nuclear fuel oxidation rates

Technical Report ·
DOI:https://doi.org/10.2172/353245· OSTI ID:353245

A detailed thermal analysis was completed of the sample temperatures in the Thermo-Gravimetric Analysis (TGA) system used to measure irradiated N Reactor fuel oxidation rates. Sample temperatures during the oxidation process did not show the increase which was postulated as a result of the exothermic reactions. The analysis shows the axial conduction of heat in the sample holder effectively removes the added heat and only a very small, i.e., <10 C, increase in temperature is calculated. A room temperature evaporation test with water showed the sample thermocouple sensitivity to be more than adequate to account for a temperature change of approximately 5 C. Therefore, measured temperatures in the TGA are within approximately 10 C of the actual sample temperatures and no adjustments to reported data to account for the heat input from the oxidation process are necessary.

Research Organization:
Fluor Daniel Hanford, Inc., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
353245
Report Number(s):
HNF-1506; ON: DE99050303; BR: EW7040000; TRN: AHC29923%%76
Resource Relation:
Other Information: PBD: 9 Oct 1997
Country of Publication:
United States
Language:
English