Post-decontamination and dismantlement (D&D) characterization report for CFA-669 site
- Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)
This report presents results of post-decontamination and dismantling (D&D) characterization surveys performed by EG&G Idaho, Inc. (EG&G Idaho), at Central Facilities Area (CFA)-669, which was the Hot Laundry Facility. The site was characterized to determine and document the radiological and chemical conditions of the site following D&D and to determine if the site satisfies the release criteria. Constructed in 1950, CFA-669 served as the ``hot`` and ``cold`` laundry for Idaho National Engineering Laboratory site contractors until the boiler exploded in 1981. The building was shut down at that time. Before D&D activities began in 1992, the facility was characterized and the results documented. D&D activities were completed in July 1994. The post-D&D radiological characterization consisted of radiation measurements and analyses of soil samples to identify man-made radionuclides and determine the specific activity of each sample. The chemical characterization consisted of toxicity characterization leaching procedure (TCLP) analysis for metals and for volatile and semivolatile organic contamination.
- Research Organization:
- Lockheed Idaho Technologies Co., Idaho Falls, ID (United States); EG and G Idaho, Inc., Idaho Falls, ID (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC07-94ID13223
- OSTI ID:
- 34454
- Report Number(s):
- INEL-94/0138; ON: DE95008670; TRN: 95:008982
- Resource Relation:
- Other Information: PBD: Jan 1995
- Country of Publication:
- United States
- Language:
- English