skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Operability test procedure for 244-U DCRT. Revision 1

Technical Report ·
DOI:https://doi.org/10.2172/34337· OSTI ID:34337

This OPT will insure the operability of various systems and their general equipment, used in the operation of the 244-U DCRT. Systems that will be tested include the following: Leak Detection Systems; Heat Trace System; Vessel Temperature Measurement System; Dip Tube Water System; Weight Factor and Specific Gravity System; Instrument Air System; Vessel Liquid Level System; Vessel Liquid Transfer System; and Exhauster Differential Pressure Indicating Controller System. The tests will cover checks on equipment operation and electrical interlocks, but will not cover checks on associated annunciator alarms which are covered in a separate OTP.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-87RL10930
OSTI ID:
34337
Report Number(s):
WHC-SD-ER3641-OTP-001-Rev.1; ON: DE95009104; TRN: 95:009711
Resource Relation:
Other Information: PBD: 13 Mar 1995
Country of Publication:
United States
Language:
English