Title: A demonstration of the gross count tomographic gamma scanner (GC-TGS) method for the nondestructive assay of transuranic waste

Technical Report ·
DOI:https://doi.org/10.2172/335195· OSTI ID:335195

The authors examined the accuracy and sensitivity levels for three variations on the TGS method: the original TGS method using a high-purity germanium (HPGe) detector to measure net areas of full-energy gamma-ray peaks; a modified HPGe-detector method that uses net areas for the transmission analysis and the gross count TGS (GC-TGS) method for the emission analysis; and a NaI-detector method that uses the GC-TGS method exclusively. They found that while the accuracies of the methods were comparable, the GC-TGS method boosted the sensitivity per detector by a factor of approximately two for the HPGe GC variation and four for the NaI method. The implications for improved TGS scanner design are discussed.

Research Organization:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
335195
Report Number(s):
LA-UR-98-3248; CONF-980733-; ON: DE99002304; TRN: 99:005049
Resource Relation:
Conference: 39. Institute of Nuclear Materials Management (INMM) annual meeting, Naples, FL (United States), 26-30 Jul 1998; Other Information: PBD: [1998]
Country of Publication:
United States
Language:
English