Title: Alternatives generation and analysis for the Phase I intermediate waste feed staging system design requirements

Technical Report ·
DOI:https://doi.org/10.2172/327048· OSTI ID:327048

This alternatives generation and analysis (AGA) addresses the question: What is the design basis for the facilities required to stage low-level waste (LLW) feed to the Phase I private contractors? Alternative designs for the intermediate waste feed staging system were developed, analyzed, and compared. Based on these analyses, this document recommends installing mixer pumps in the central pump pit of double-shell tanks 241-AP-102 and 241-AP-104. Also recommended is installing decant/transfer pumps at these tanks. These recommendations have clear advantages in that they provide a low shedule impact/risk and the highest operability of all the alternatives investigated. This revision incorporates comments from the decision board.

Research Organization:
Fluor Daniel Hanford, Inc., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
327048
Report Number(s):
HNF-SD-TWR-AGA-001-Rev.1; ON: DE98059578; BR: EW3130010; TRN: 97000102
Resource Relation:
Other Information: PBD: 6 Feb 1997
Country of Publication:
United States
Language:
English